HBP Series Dryers produce 100% efficient air systems. Since 1948, compressed air users have relied on Hankison to provide compressed air treatment solutions for applications around the world. HBP Series dryers improve air system efficiency by the use of a dedicated axial blower, instead of a percentage of dehydrated purge air, to regenerate the off-line desiccant tower. ISO 8573.1 Class 2 (-40°F/-40°C) dew point performance is guaranteed.
As the air compressor is the most costly system component to purchase and, it uses more electrical energy than the rest of the system combined, it is wise to ensure that the smallest air compressor is installed. HBP Series dryers are 100% efficient at delivering full supply-side compressor capacity. Therefore, users benefit from the ability to purchase a less expensive air compressor and, a 20% reduction in compressor operating costs.
Model |
Flow Capacity (NM3/min) |
Dimension(mm) |
Inlet / Outlet Connection (FLG) |
Blower (kW) |
Heater Rated Output (kW) |
Full Load (average, kW) |
Weight (kg) |
||
H |
W |
D |
|||||||
HBP 14.1 |
14.16 |
2664 |
1346 |
1491 |
2” PT |
1.75 |
10 |
10 |
846 |
HBP 16.9 |
16.99 |
2753 |
1397 |
1531 |
2” PT |
2.55 |
12 |
12 |
958 |
HBP 21.2 |
21.24 |
2903 |
1524 |
1734 |
3” FLG |
2.55 |
14 |
14 |
1114 |
HBP 25.4 |
25.49 |
2903 |
1524 |
1734 |
3” FLG |
4.6 |
16 |
16 |
1121 |
HBP 29.7 |
29.73 |
3050 |
1495 |
1800 |
3” FLG |
3.7 |
19 |
16 |
1352 |
HBP 36.8 |
36.81 |
3025 |
1598 |
1800 |
3” FLG |
6.3 |
23 |
18 |
1622 |
HBP 42.4 |
42.48 |
3050 |
1648 |
1950 |
3” FLG |
8.6 |
28 |
21 |
2431 |
HBP 50.9 |
50.97 |
3050 |
1780 |
1950 |
3” FLG |
8.6 |
33 |
26 |
2431 |
HBP 62.2 |
62.30 |
3200 |
2004 |
2050 |
4” FLG |
12.6 |
40 |
34 |
3637 |
HBP 73.6 |
73.62 |
3350 |
1778 |
2200 |
4” FLG |
11.0 |
45 |
36 |
3685 |
HBP 90.6 |
90.61 |
3460 |
2250 |
2800 |
4” FLG |
5.6 |
54 |
38 |
4233 |
HBP 101.9 |
101.94 |
3500 |
2350 |
2900 |
6” FLG |
7.5 |
60 |
45 |
4460 |
HBP 121.7 |
121.76 |
3460 |
2350 |
3050 |
6” FLG |
7.5 |
70 |
50 |
5602 |
Since 1948, sensitive applications requiring clean, dry, compressed air have turned to Hankison for the optimal solution. Utilizing twin towers filled with premium grade activated alumina, Hankison Heatless dyers are available with 3 application specific control systems to rreet the needs of industry with economy and Performance. Hankison HF18 HHL or HHE Series heatless desiccant dryers provide consistent outlet pressi re dew points to -100°F (-73°C).
Microelectronics, food packaging, paper, glass, pharmaceutical, powder painting hospital laboratories: these industries are a small representative sample of in di stries utilizing desiccant dryers. They all have one thing in common._ they need to save space on the factory/laboratory floor. HH Seriei sleek designs and compact footprints help engineers address those needs.
Premium grace desiccant beads offer enhanced surface area and high crush strength vhidi prolongs bed life
Large desiccant beds ensure 4.8 seconds of contact time…allows wet, saturated air at the dyer inlet to be dried to the required dew point
30% extra desiccant provided to compensate for natural bed aging…ensures top performance over expected 3 to 5 years of desiccant bed life
Large flow diffuses ensure even flow distribution through the bed and eliminate channeling
Towers are sired so that air velocity through he bed won’t fluidize the desiccant which prevents bed movement and desiccant dusting
Up-flow drying a loins water and heavy contaminants to drop out of the air stream as they enter a tower which Protects the bed from contamination. This makes it simple to discharge he contaminants when the tower depressurizes.
Cleanable stainless steel how diffuses / support screens and separate fill and drain ports for ease of desiccant replacement
Pressure vessels are ASME Certified (Option: consult factory for the local vessel code)
Heavy-duty mufflers for quiet operation – dyers shipped with an extra set of mufflers
NEMA 4 electrical construction is standard
Pressure relief valves are standard
Model |
Flow Capacity (NM3/min) |
Dimension(mm) |
Inlet / Outlet |
Weight (kg) |
||
H |
W |
D |
||||
HHS / HHL / HHE 1.1 |
1.13 |
1235 |
884 |
884 |
1” PT |
166 |
HHS / HHL / HHE 1.6 |
1.69 |
1616 |
884 |
884 |
1” PT |
202 |
HHS / HHL / HHE 2.5 |
2.55 |
2047 |
984 |
984 |
1” PT |
261 |
HHS / HHL / HHE 3.2 |
3.26 |
1437 |
1264 |
1264 |
1” PT |
311 |
HHS / HHL / HHE 4.6 |
4.67 |
1437 |
1264 |
1264 |
1” PT |
311 |
HHS / HHL / HHE 7.3 |
7.37 |
1894 |
1305 |
1305 |
2” PT |
458 |
HHS / HHL / HHE 10.4 |
10.48 |
1658 |
1470 |
1470 |
2” PT |
551 |
HHS / HHL / HHE 12.7 |
12.74 |
1861 |
1470 |
1470 |
2” PT |
612 |
HHS / HHL / HHE 16.7 |
16.71 |
2631 |
1387 |
1387 |
2” PT |
668 |
HHS / HHL / HHE 21.2 |
21.24 |
2720 |
1438 |
1438 |
2” PT |
968 |
HHS / HHL / HHE 26.3 |
26.33 |
2841 |
1603 |
1603 |
2” PT |
1095 |
HHS / HHL / HHE 31.9 |
32.00 |
2924 |
1673 |
1673 |
3” FLG |
1304 |
HHS / HHL / HHE 38.2 |
38.23 |
3051 |
1724 |
1724 |
3” FLG |
1688 |
HHS / HHL / HHE 43.8 |
43.89 |
2980 |
1876 |
1876 |
4” FLG |
1890 |
HHS / HHL / HHE 59.4 |
59.47 |
3026 |
2080 |
2080 |
4” FLG |
2004 |
HHS / HHL / HHE 84.9 |
84.95 |
3180 |
2172 |
2172 |
4” FLG |
4087 |
HHS / HHL / HHE 116.0 |
116.10 |
3158 |
2537 |
2537 |
6” FLG |
4500 |
HHS / HHL / HHE 152.9 |
152.91 |
3158 |
2667 |
2667 |
6” FLG |
5445 |
Since 1948, compressed air users have relied on Hankison to provide compressed air treatment products with integrity. Global demand for Air Quality Class 3 and our advanced Ambient Air Amplification (A3) Purge Technology'” wades us to offer you externally heated purge desiccant dryers with dew mint performance guaranteed tom 8.5 to 90.6 Nm3/min.
Designed for applicantions that were previously forced to accept a -40°C pressure dew point when simple protection against seasonal freezing is the issue. The standard design delivers ISO 8573.1 dew points between Class 2 and Claw 3 automatically. Class 2 (-40°C) dew mints protect against freezing during low ambient conditions and Class 3 (-20°C) dew mints keep your air system bone dry during the heat of summer. applications that require Class 2 (-40°C) dew points year round simply need to select the Free-Air (FA) Supercharger option package.
Model |
Flow Capacity (NM3/min) |
Heater Rated Output (kW) |
Average (kW) |
Dimension(mm) |
Inlet / Outlet |
Weight (kg) |
||
H |
W |
D |
||||||
HPD 8.5 |
8.50 |
4.5 |
2.00 |
2480 |
1207 |
1164 |
1 – 1/2” |
617 |
HPD 11.3 |
11.33 |
6.0 |
2.67 |
2649 |
1346 |
1315 |
1 – 1/2” |
806 |
HPD 14.1 |
14.16 |
6.0 |
3.34 |
2664 |
1346 |
1315 |
2” PT |
806 |
HPD 16.9 |
16.99 |
8.0 |
4.01 |
2753 |
1397 |
1340 |
2” PT |
897 |
HPD 21.2 |
21.24 |
10.0 |
5.01 |
2903 |
1524 |
1503 |
3” FLG |
1054 |
HPD 25.4 |
25.49 |
12.0 |
6.01 |
2895 |
1524 |
1503 |
3” FLG |
1061 |
HPD 29.7 |
29.73 |
14.0 |
7.01 |
2870 |
1626 |
1580 |
3” FLG |
1277 |
HPD 36.8 |
36.81 |
16.0 |
8.68 |
2997 |
1676 |
1605 |
3” FLG |
1509 |
HPD 42.4 |
42.48 |
19.0 |
10.00 |
2946 |
2032 |
1682 |
3” FLG |
2311 |
HPD 50.9 |
50.97 |
23.0 |
12.00 |
2946 |
2032 |
1682 |
3” FLG |
2311 |
HPD 62.2 |
62.30 |
27.5 |
14.70 |
3246 |
2159 |
1855 |
4” FLG |
3517 |
HPD 73.6 |
73.62 |
32.0 |
17.40 |
3246 |
2159 |
1855 |
4” FLG |
3517 |
HPD 90.6 |
90.61 |
39.0 |
21.40 |
3183 |
2464 |
2090 |
6” FLG |
4066 |
Produces pressure dew point of -40°C
Fully Enclosed Wall-mounted Package delivers dew points of ISO 8573.1 Class 2 (-40°C, -40°F). Labs, Hospitals, and Hi-Tech installations all benefit with dry air and more floor space.
Highly accurate solid state timer
Front mounted control panel
HK Series coalescing filter packages
(top and bottom of vessels)
Model |
Flow Capacity (NM3/min) |
Unit (kW) |
Power Supply |
Inlet / Outlet |
Dimension(mm) |
Weight (kg) |
||
H |
W |
D |
||||||
HDW 0.2 |
0.29 |
0.05 |
220 – 240 V |
PT 1/2” |
775 |
445 |
170 |
25 |
HDW 0.4 |
0.43 |
775 |
445 |
170 |
27 |
|||
HDW 0.5 |
0.58 |
775 |
445 |
170 |
32 |
|||
HDW 0.7 |
0.72 |
803 |
619 |
217 |
42 |
|||
HDW 1.0 |
1.01 |
803 |
619 |
217 |
45 |
Produces pressure dew point of -40°C
Delivers dew points of ISO 8573.1 Class 2 (-40°C, -40°F). Labs, Hospitals, Hi-Tech, and Light Industrial installations all benefit with dry air and more floor space.
Highly accurate solid state timer
Accurate and durable process valves
(top and bottom of vessels)
Model |
Flow Capacity (NM3/min) |
Unit (kW) |
Power Supply |
Inlet / Outlet |
Dimension(mm) |
Weight (kg) |
||
H |
W |
D |
||||||
HEA 1.5 |
1.56 |
0.05 |
220 – 240 V |
PT 1” |
1193 |
720 |
700 |
45 |
HEA 2.8 |
2.89 |
1725 |
720 |
700 |
95 |
|||
HEA 4.6 |
4.63 |
1637 |
820 |
700 |
125 |
|||
HEA 5.7 |
5.79 |
PT 2” |
1905 |
825 |
700 |
175 |
||
HEA 7.9 |
7.96 |
1765 |
975 |
800 |
225 |
|||
HEA 10.1 |
10.13 |
1653 |
1055 |
800 |
326 |
|||
HEA 13.7 |
13.74 |
1783 |
1125 |
800 |
517 |
|||
HEA 17.3 |
17.36 |
1745 |
1235 |
800 |
761 |
Moisture can be a real problem in a compressed air system. The air outlet temperature of a compressor / after-cooler package is typically 25-50C and saturated with water vapor, which results in significant amounts of liquid downstream. The moisture in a compressed air system can cause serious problems ranging from products spoilage to equipment malfunction, thus making an air dryer is a critical component in any compressed air system.
Our HDB series compressed air dryer reduces the concentration of water vapor and decreases the pressure dew point of the air to -40C (Optional: -73C)
HDB compressed air dryers use porous materials (desiccants) to adsorb moisture from the compressed air. For regeneration, heated ambient air is used instead of expensive purge air to desorb moisture from the regenerating bed. No purge loss means DRYER-IN is almost same as DRYER-OUT.
Model |
Flow Capacity (NM3/min) |
Heater (kW) |
Power Consumption |
Fan (kW) |
In / Out |
Dimension(mm) |
Weight (kg) |
||
H |
W |
D |
|||||||
HDB 28.3 |
28.33 |
23 |
16.5 |
3 |
DN80 |
2864 |
2400 |
1640 |
2150 |
HDB 35.0 |
35.00 |
27 |
18.5 |
3 |
DN80 |
2950 |
2400 |
1640 |
2340 |
HDB 41.6 |
41.67 |
31 |
21.3 |
5.5 |
DN80 |
2872 |
2700 |
1730 |
2700 |
HDB 48.3 |
48.33 |
39 |
26.7 |
5.5 |
DN100 |
2872 |
2800 |
1840 |
3250 |
HDB 55.0 |
55.00 |
42 |
30 |
5.5 |
DN100 |
3100 |
2800 |
1840 |
3560 |
HDB 70.0 |
70.00 |
51 |
35.7 |
5.5 |
DN150 |
3136 |
3350 |
1695 |
4200 |
HDB 88.3 |
88.33 |
66 |
46.5 |
7.5 |
DN150 |
3220 |
3350 |
2180 |
5400 |
HDB 100.0 |
100.00 |
82 |
57.5 |
7.5 |
DN150 |
3327 |
3800 |
2280 |
6900 |
HDB 116.6 |
116.67 |
85 |
61 |
7.5 |
DN150 |
3200 |
4000 |
2360 |
7100 |
HDB 133.3 |
133.33 |
101 |
70.3 |
11 |
DN150 |
2800 |
5070 |
2190 |
8200 |
HDB 141.6 |
141.67 |
113 |
78.7 |
11 |
DN200 |
3050 |
5270 |
2360 |
9800 |
HDB 183.3 |
183.33 |
132 |
92.8 |
11 |
DN200 |
3050 |
5370 |
2445 |
11000 |
HDB 225.0 |
225.00 |
164 |
113.8 |
15 |
DN200 |
3100 |
5670 |
2643 |
14500 |
HDB 250.0 |
250.00 |
200 |
156 |
16 |
DN250 |
3535 |
5770 |
2765 |
15950 |
HDB 300.0 |
300.00 |
244 |
191 |
20 |
DN250 |
3606 |
6059 |
2903 |
17545 |
HDB 333.3 |
333.33 |
273 |
213 |
22 |
DN300 |
3678 |
6362 |
3048 |
19300 |
HDB 383.3 |
383.33 |
310 |
243 |
25 |
DN300 |
3715 |
6680 |
3200 |
21230 |
HDB 450.0 |
450.00 |
356 |
278 |
29 |
DN300 |
3752 |
7014 |
3360 |
23353 |
HDB 533.3 |
533.33 |
432 |
338 |
35 |
DN350 |
3790 |
7365 |
3528 |
25688 |
HDB 616.6 |
616.67 |
496 |
388 |
40 |
DN350 |
3411 |
7733 |
3704 |
28257 |
HDB 766.6 |
766.67 |
611 |
478 |
49 |
DN400 |
3752 |
8120 |
3889 |
31083 |